Central venous catheter

…cooperate — consider sedation, a different position or a different vessel. Choice of site Vessel Advantages Disadvantages : : : Internal jugular vein (right) Best ultrasound conditions, a straight…

ArticleEchocardiography
Artifacts in ultrasound imaging

…Depending on the difference in acoustic impedance between the tissues, the angle of the ultrasound wave may be altered. This is referred to as refraction …

ArticleEchocardiography
The ultrasound transducer

…ultrasound machine for analysis. The reflected sound waves will have the same speed as the emitted sound waves, but the amplitude, frequency and angle of…

ArticleEchocardiography
Optimization of the ultrasound image

…high frequency waves. The frequency of the ultrasound wave must generally be reduced in order to visualize objects located far away from the transducer. Hence…

ArticleEchocardiography
Physics of ultrasound

…and ultrasound physics Unlike light waves, which can propagate through vacuum, sound waves can only propagate through a physical medium. This medium may consist of…

ArticleEchocardiography
Technical aspects of the ultrasound image

…frequency) . This is actually exploited to calculate the direction and speed of tissue and fluid movements. All structures in a medium can reflect ultrasound waves…

ArticleEchocardiography
Two-dimensional (2D) echocardiography

…To create an image sector of 90° width and 15 cm depth, approximately 200 ultrasound lines are required and this takes about 40 milliseconds (ms…

ArticleEchocardiography
Continuous Wave Doppler (CW Doppler)

…Doppler (CW Doppler), ultrasound waves are continuously emitted from the transducer and the reflections of these waves are analyzed continuously (Figure 1). This is possible…

ArticleEchocardiography
Pulsed Wave Doppler

Echocardiography Pulsed Wave Doppler The pulsed wave Doppler (PW Doppler) sends short pulses of ultrasound and analyzes reflected sound waves between the pulses. This is…

ArticleProcedurer
Paracentesis

…renal failure or simply deterioration. The procedure itself is straightforward: ultrasound to find the fluid, an insertion site in the left lower quadrant lateral to…

ArticleProcedurer
Pericardiocentesis

…and where no liver, lung or vessel lies in the path of the needle. Access Puncture site Direction Comment : : : : Subxiphoid 1–2 cm below and…

ArticleProcedurer
Pleural aspiration and chest drain

…puncture site Relative Mechanical ventilation with a high PEEP (an increased risk of pneumothorax; ultrasound guidance is mandatory) Relative A very small or loculated effusion …

ArticleMyocardial ischemia and infarction
Intravascular Imaging: IVUS and OCT for PCI Optimisation

…endothelial coverage. Complementary Characteristics IVUS and OCT are complementary rather than interchangeable. IVUS generally provides better visualization of overall vessel dimensions, plaque burden, large vess

ArticleInfo
🚫 Our friends

…Ryan Lafollette and Bill Hinckley run this amazing website which includes everything from ultrasound knobology and emergency procedures to practice guidelines for emergency medicine (and…

ArticleEchocardiography
Left ventricular mass and volume (size)

…The ultrasound system automatically calculates RWT (Relative Weight Thickness), provided that the patient's weight, height and sex are entered. RWT is a measure of…

ArticleEchocardiography
M-mode (motion mode) echocardiography

…single ultrasound line, its temporal and axial resolution is very high, as compared with 2D echocardiography. M mode is useful for quantifying the mobility of…

ArticleEchocardiography
Performing Echocardiographic Examinations

…during the examination. Work related musculoskeletal disorders are a common cause of pain and sickness absence for ultrasound practitioners (Harrison et al). When performing emergency…

ArticleEchocardiography
Tissue Doppler (Tissue Velocity Imaging)

…density of myocardium. It follows that myocardium generates reflections with high amplitude and low Doppler shift. To analyze reflections from the myocardium, the ultrasound machine…

ArticleProcedurer
Abscess incision and drainage

…picture without a demarcated fluid collection. Ultrasound also shows the depth of the cavity and its distance to vessels. Contraindications and when to involve a…

ArticleProcedurer
Ankle-brachial index (ABI)

Procedurer The ankle brachial index is the cheapest and most accessible method of objectively demonstrating peripheral arterial disease, and it is needed more often than…

ArticleCardiology
Coronary Anomalies and Myocardial Bridging

…However, intravascular ultrasound has shown that delayed opening of the bridged segment may extend into diastole, so the physiological effect is not limited to systole…

ArticleEchocardiography
Stress Echocardiography: Protocols and Interpretation

…coronary artery disease (CAD). It combines echocardiographic assessment of left ventricular (LV) structure and function with exercise or pharmacological stress. The physiological basis is an…

ArticleEchocardiography
Assessing left ventricular systolic function

…speed and direction of myocardial motion. This is possible because myocardium also reflects ultrasound waves. In order to analyze myocardial motion, the ultrasound system must…

ArticleProcedurer
Arterial line

…and a warm, well perfused hand carry more weight. Choice of vessel The radial artery is the first choice : superficial, easy to compress, with a…

ArticleReferensvärden
Liver parameters

…ultrasound of the liver and biliary tract . Go through the medication and any herbal preparations carefully — drug induced liver injury is the commonest cause of…

ArticleProcedurer
Peripheral venous cannula and intraosseous access

…risk of rapid deterioration. Intraosseous access: Cardiac arrest where venous access is not immediately available. Shock, severe trauma, burns or status epilepticus when peripheral access…

ArticleEchocardiography
Color Doppler

…Large variations in velocities recorded within a single sample volume indicate turbulent flow; the ultrasound machine is programmed to depict such flows with green color…

ArticleEchocardiography
Doppler effect and Doppler echocardiography

…to be detected and analyzed by the ultrasound machine. Figure 2. Reflections from an erythrocyte. Flowing erythrocytes will alter the frequency of reflected sound waves…

ArticleEchocardiography
Pericardial Effusion & Cardiac tamponade

…the myocardium. At the departures of the larger vessels, the visceral layer is folded back to cover the inside of the parietal layer. Between the…