43 träffar

ArticleProcedurer
Central venous catheter

…Indications Infusion of vesicant solutions: vasopressors, concentrated potassium, cytotoxic drugs, parenteral nutrition. The need for several simultaneous, incompatible infusions. Haemodialysis, plasmapheresis or other extracorporeal therapy …

ArticleEchocardiography
Artifacts in ultrasound imaging

…Depending on the difference in acoustic impedance between the tissues, the angle of the ultrasound wave may be altered. This is referred to as refraction …

ArticleEchocardiography
The ultrasound transducer

…Figure 2, the ultrasound transducer contains several components. The transducer contains acoustic insulation that ensures that no other sound waves affect the transducer. The crystals…

ArticleEchocardiography
Optimization of the ultrasound image

…high frequency waves. The frequency of the ultrasound wave must generally be reduced in order to visualize objects located far away from the transducer. Hence…

ArticleEchocardiography
Physics of ultrasound

…and ultrasound physics Unlike light waves, which can propagate through vacuum, sound waves can only propagate through a physical medium. This medium may consist of…

ArticleEchocardiography
Technical aspects of the ultrasound image

…frequency) . This is actually exploited to calculate the direction and speed of tissue and fluid movements. All structures in a medium can reflect ultrasound waves…

ArticleEchocardiography
Two-dimensional (2D) echocardiography

…To create an image sector of 90° width and 15 cm depth, approximately 200 ultrasound lines are required and this takes about 40 milliseconds (ms…

ArticleEchocardiography
Continuous Wave Doppler (CW Doppler)

…1). This is possible by using two different sets of piezoelectric crystals; one set for sending ultrasound and the other for analyzing reflected sound waves…

ArticleEchocardiography
Pulsed Wave Doppler

Echocardiography Pulsed Wave Doppler The pulsed wave Doppler (PW Doppler) sends short pulses of ultrasound and analyzes reflected sound waves between the pulses. This is…

ArticleProcedurer
Paracentesis

…renal failure or simply deterioration. The procedure itself is straightforward: ultrasound to find the fluid, an insertion site in the left lower quadrant lateral to…

ArticleProcedurer
Pericardiocentesis

…and where no liver, lung or vessel lies in the path of the needle. Access Puncture site Direction Comment : : : : Subxiphoid 1–2 cm below and…

ArticleProcedurer
Pleural aspiration and chest drain

…puncture site Relative Mechanical ventilation with a high PEEP (an increased risk of pneumothorax; ultrasound guidance is mandatory) Relative A very small or loculated effusion …

ArticleMyocardial ischemia and infarction
Intravascular Imaging: IVUS and OCT for PCI Optimisation

…endothelial coverage. Complementary Characteristics IVUS and OCT are complementary rather than interchangeable. IVUS generally provides better visualization of overall vessel dimensions, plaque burden, large vess

ArticleInfo
🚫 Our friends

…Ryan Lafollette and Bill Hinckley run this amazing website which includes everything from ultrasound knobology and emergency procedures to practice guidelines for emergency medicine (and…

ArticleEchocardiography
Cardiac thromboembolism: cardiac sources of embolism

…Ultrasound may reveal atherosclerotic plaques, thrombi, occlusions, and dissections. Stroke is subdivided into hemorrhagic stroke (13% of all cases) and ischemic stroke (87% of all…

ArticleEchocardiography
Left ventricular mass and volume (size)

…The ultrasound system automatically calculates RWT (Relative Weight Thickness), provided that the patient's weight, height and sex are entered. RWT is a measure of…

ArticleEchocardiography
M-mode (motion mode) echocardiography

…single ultrasound line, its temporal and axial resolution is very high, as compared with 2D echocardiography. M mode is useful for quantifying the mobility of…

ArticleEchocardiography
Performing Echocardiographic Examinations

…during the examination. Work related musculoskeletal disorders are a common cause of pain and sickness absence for ultrasound practitioners (Harrison et al). When performing emergency…

ArticleEchocardiography
Tissue Doppler (Tissue Velocity Imaging)

…shift. To analyze reflections from the myocardium, the ultrasound machine filters out all other reflected sound waves, such that only those representing myocardium are recorded…

ArticleProcedurer
Abscess incision and drainage

…Orthopaedic surgeon Close to large vessels, in the groin or on the neck Bleeding, vascular injury, pseudoaneurysm Surgeon, ultrasound first Other situations that argue for…

ArticleProcedurer
Ankle-brachial index (ABI)

…pressure in that leg ÷ highest arm pressure of the two arms Interpretation ABI Interpretation Action : : : 1.40 Incompressible vessels — medial sclerosis Measure the toe pressure…

ArticleCardiology
Coronary Anomalies and Myocardial Bridging

…cardiac chamber or vessel. Other congenital anomalies include anomalous origin of a coronary artery from the pulmonary artery and anomalous origin of one coronary artery…

ArticleEchocardiography
Stress Echocardiography: Protocols and Interpretation

…hypertrophy, LV dysfunction, or other pathology that could affect the safety or interpretation of the examination. Evaluation and Physical Examination Before stress echocardiography, clinical assessment…

ArticleEchocardiography
Assessing left ventricular systolic function

…because myocardium also reflects ultrasound waves. In order to analyze myocardial motion, the ultrasound system must filter out all sound waves reflected by other structures…

ArticleProcedurer
Arterial line

…and a warm, well perfused hand carry more weight. Choice of vessel The radial artery is the first choice : superficial, easy to compress, with a…

ArticleReferensvärden
Liver parameters

…A markedly raised GGT with the other tests normal is most often enzyme induction by alcohol or drugs and is often of no clinical significance…

ArticleCardiology
Abdominal Aortic Aneurysm: Screening and Surveillance

…by radiography. Assessment should include consideration of associated vascular disease. In patients with AAA, duplex ultrasound screening for femoropopliteal aneurysms should be considered. Opportunistic screening…

ArticleEchocardiography
Color Doppler

…Large variations in velocities recorded within a single sample volume indicate turbulent flow; the ultrasound machine is programmed to depict such flows with green color…

ArticleEchocardiography
Doppler effect and Doppler echocardiography

…to be detected and analyzed by the ultrasound machine. Figure 2. Reflections from an erythrocyte. Flowing erythrocytes will alter the frequency of reflected sound waves…

ArticleEchocardiography
Pericardial Effusion & Cardiac tamponade

…blood tests and other radiological examinations are most often required, in particular computed tomography (DT) and/or magnetic resonance imaging (MRI). Anatomy of the pericardium…